256GB
Users Manual
(Field Network)
Read this manual before use.
After you read this manual, keep it in a safe place for future
reference.
Vision Sensor
IV Series
1
Getting Started
4
PROFINET
2
EtherNet/IP
5
Data I/O communication
3
Cyclic communication
A
Reference program
Przeglądanie stron 0
1 2 3 4 5 6 ... 109 110

Podsumowanie treści

Strona 1 - IV Series

256GBUser’s Manual(Field Network)Read this manual before use.After you read this manual, keep it in a safe place for future reference.Vision SensorIV

Strona 2 - Introduction

8- IV Series User’s Manual (Field Network) -ContentsIntroductionSymbolsCautionsSafety Information for IV Series...1General

Strona 3 - General Precautions

A-6- IV Series User’s Manual (Field Network) -Reference program (EtherNet/IP)Program switchingKeyence KV seriesLine 1Line 2Line 3REQProgram switching

Strona 4 - Important Instructions

A-7- IV Series User’s Manual (Field Network) -Reference program (EtherNet/IP)Rockwell Automation PLCRung0Rung1REQONSONSProgram ChangeMOVMoveSourceDest

Strona 5 - Precautions on installation

A-8- IV Series User’s Manual (Field Network) -Reference program (PROFINET)This section introduces a reference program for when using the PROFINET comm

Strona 6 - IV-2000M/IV-2000MA

A-9- IV Series User’s Manual (Field Network) -Reference program (PROFINET)Handshake control [Enabled]Siemens PLCNetwork1Network2Network3REQPPPMOVENINR

Strona 7 - Version of the IV Series

A-10- IV Series User’s Manual (Field Network) -Reference program (PROFINET)Program switchingSiemens PLCNetwork1Network2PPMOVENINProgram NumberENOOUTNu

Strona 8 - IV-Navigator (IV-H1)

A-11- IV Series User’s Manual (Field Network) -Reference program (PROFINET)MEMOA

Strona 9 - Structure of This Manual

A-12- IV Series User’s Manual (Field Network) -IndexIndexBBasic congurations of IV-Series ...1-2CConnecting the host device and

Strona 10 - Contents

A-13- IV Series User’s Manual (Field Network) -IndexTTool Result Modules (IV series→ PLC) ...5-19WWarning code list ...

Strona 11 - Chapter 4 PROFINET

Revision historyRevision historyEdition numberRevision detailsDecember, 2012 1st editionDecember, 2013 2nd edition Ethernet and Monitor cable changedA

Strona 12

WARRANTIES AND DISCLAIMERS(1) KEYENCE warrants the Products to be free of defects in materials and workmanship for a period of one (1) year from the

Strona 13 - Getting Started

9- IV Series User’s Manual (Field Network) -ContentsChapter 4 PROFINETOverview of PROFINET ...4-2What is PROFINET?

Strona 14 - System Conguration

244008E 1044-3 256GB2012

Strona 15

10- IV Series User’s Manual (Field Network) -ContentsMEMO

Strona 16 - Overview of IV Series

1-1- IV Series User’s Manual (Field Network) -This chapter explains the system congurations and overview of IV Series.System Conguration ...

Strona 17

1-2- IV Series User’s Manual (Field Network) -System CongurationBasic congurations of IV-SeriesConnecting the host device and single sensorIn additi

Strona 18

1-3- IV Series User’s Manual (Field Network) -System CongurationConnecting the host device and multiple sensorsEthernet cable(2m/5m/10m)Ethernet swit

Strona 19 - EtherNet/IP

1-4- IV Series User’s Manual (Field Network) -Overview of IV SeriesOverview of IV SeriesIV SeriesThe IV Series is an all-in-one “Vision Sensor” featur

Strona 20 - Overview of EtherNet/IP

1-5- IV Series User’s Manual (Field Network) -Overview of IV SeriesOperation of the indicator lightDetails on operations of the indicator light are sh

Strona 21

1-6- IV Series User’s Manual (Field Network) -Overview of IV SeriesMEMO1Getting Started

Strona 22 - List of supported PLCs

2-1- IV Series User’s Manual (Field Network) -This chapter describes the overview of EtherNet/IP and the communication specications and functions of

Strona 23

IntroductionIntroductionRead this manual before using the product in order to achieve maximum performance.Keep this manual in a safe place after readi

Strona 24 - What is cyclic communication?

2-2- IV Series User’s Manual (Field Network) -Overview of EtherNet/IPWhat is EtherNet/IP?EtherNet/IP is an open industrial networking standard develop

Strona 25 - Setting the IV series

2-3- IV Series User’s Manual (Field Network) -EtherNet/IP communication specications and functions in the IV seriesEtherNet/IP communication specica

Strona 26

2-4- IV Series User’s Manual (Field Network) -EtherNet/IP communication specications and functions in the IV seriesList of supported PLCsCheck the in

Strona 27 - PLC settings

3-1- IV Series User’s Manual (Field Network) -This chapter describes the overview, setting method, data allocation, and operating procedure of the cyc

Strona 28

3-2- IV Series User’s Manual (Field Network) -Overview of the cyclic communicationWhat is cyclic communication?This function enables cyclic (i.e. in 

Strona 29 - Keyence KV series settings

3-3- IV Series User’s Manual (Field Network) -Cyclic communication setting methodCyclic communication setting methodThis following explains the settin

Strona 30

3-4- IV Series User’s Manual (Field Network) -Cyclic communication setting methodWhen setting by IV-Navigator (IV-H1)Set the eld network settings of

Strona 31

3-5- IV Series User’s Manual (Field Network) -Cyclic communication setting methodPLC settingsYou can set the following settings for the PLC: (1) Set t

Strona 32

3-6- IV Series User’s Manual (Field Network) -Cyclic communication setting methodThere are many types of connections, and the connection available for

Strona 33

3-7- IV Series User’s Manual (Field Network) -Cyclic communication setting methodKeyence KV series settingsThis following explains the setting method

Strona 34

1Safety Information for IV Series256GBGeneral Precautions Do not use this product for the purpose to protect a human body or a part of human body. T

Strona 35

3-8- IV Series User’s Manual (Field Network) -Cyclic communication setting method6 Select [Device comment edit window] from the [Edit] menu in KV STUD

Strona 36 - Warning No

3-9- IV Series User’s Manual (Field Network) -Cyclic communication setting method3 Modify the settings as necessary. Name (Device name)You can assig

Strona 37

3-10- IV Series User’s Manual (Field Network) -Data allocation in the cyclic communicationInput Assembly (IV series → PLC)Input Assembly are devices t

Strona 38

3-11- IV Series User’s Manual (Field Network) -Data allocation in the cyclic communicationAddress Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit054 - 55Positi

Strona 39

3-12- IV Series User’s Manual (Field Network) -Data allocation in the cyclic communicationInput Assembly parameter detailsInput Assembly Address 0:

Strona 40

3-13- IV Series User’s Manual (Field Network) -Data allocation in the cyclic communicationInput Assembly Address 2 to 3: Handshake control/status/er

Strona 41

3-14- IV Series User’s Manual (Field Network) -Data allocation in the cyclic communication By monitoring whether the unit is in “Imaging” status, you

Strona 42

3-15- IV Series User’s Manual (Field Network) -Data allocation in the cyclic communicationInput Assembly Address 4 to 7: Status resultThe Bits at Ad

Strona 43

3-16- IV Series User’s Manual (Field Network) -Data allocation in the cyclic communicationzInput Assembly Address 8 to 23: Error/status/status result

Strona 44 - Error code list

3-17- IV Series User’s Manual (Field Network) -Data allocation in the cyclic communicationInput Assembly Address 24 to 51: Statistics informationThe

Strona 45 - Warning code list

2- IV Series User’s Manual (Field Network) -Important InstructionsPrecautions on use The power of this product and instruments connected to this prod

Strona 46

3-18- IV Series User’s Manual (Field Network) -Data allocation in the cyclic communicationInput Assembly Address 52 to 71: Position correction infor

Strona 47 - Cyclic communication

3-19- IV Series User’s Manual (Field Network) -Data allocation in the cyclic communicationOutput Assembly (PLC → IV series)Output Assembly are devices

Strona 48 - When a trigger is successful

3-20- IV Series User’s Manual (Field Network) -Data allocation in the cyclic communicationOutput Assembly parameter detailsOutput Assembly Address 0

Strona 49

3-21- IV Series User’s Manual (Field Network) -Data allocation in the cyclic communicationOutput Assembly Address 2 to 3: Handshake controlThe Bits

Strona 50 - (Handshake control [Enabled])

3-22- IV Series User’s Manual (Field Network) -Data allocation in the cyclic communicationError code listThe following shows the list of error codes t

Strona 51 - Program switching response

3-23- IV Series User’s Manual (Field Network) -Data allocation in the cyclic communicationWarning code listThe following shows the list of warning cod

Strona 52 - Master registration response

3-24- IV Series User’s Manual (Field Network) -Data allocation in the cyclic communicationWarning codeContent Cause Countermeasure70FTP Transfer Error

Strona 53 - PROFINET

3-25- IV Series User’s Manual (Field Network) -Data allocation in the cyclic communicationMEMO3Cyclic communication

Strona 54 - Overview of PROFINET

3-26- IV Series User’s Manual (Field Network) -Operating procedure of the cyclic communicationThis section explains the method for communicating from

Strona 55 - I/O Controller

3-27- IV Series User’s Manual (Field Network) -Operating procedure of the cyclic communicationWhen a trigger is unsuccessfulTrigger requestResult of

Strona 56

3- IV Series User’s Manual (Field Network) -Important InstructionsPrecautions on installation To use this product correctly and safely, avoid install

Strona 57

3-28- IV Series User’s Manual (Field Network) -Operating procedure of the cyclic communicationReading out the overall status result of the IV series

Strona 58

3-29- IV Series User’s Manual (Field Network) -Operating procedure of the cyclic communicationSwitching the programs in the IV seriesProgram No.Progra

Strona 59 - Data I/O communication

3-30- IV Series User’s Manual (Field Network) -Operating procedure of the cyclic communicationRegistering a master image for the IV series externallyM

Strona 60

4-1- IV Series User’s Manual (Field Network) -This chapter describes the overview of PROFINET and the communication specications and functions of the

Strona 61

4-2- IV Series User’s Manual (Field Network) -Overview of PROFINETOverview of PROFINETWhat is PROFINET?PROFINET is an open industrial networking stand

Strona 62

4-3- IV Series User’s Manual (Field Network) -PROFINET communication specications and functions in the IV seriesIV series PROFINET communication spec

Strona 63 - Setting the device name

4-4- IV Series User’s Manual (Field Network) -PROFINET communication specications and functions in the IV seriesOverview of the PROFINET communicatio

Strona 64

4-5- IV Series User’s Manual (Field Network) -PROFINET communication specications and functions in the IV seriesList of supported PLCsCheck the instr

Strona 65

4-6- IV Series User’s Manual (Field Network) -PROFINET communication specications and functions in the IV seriesMEMO4PROFINET

Strona 66

5-1- IV Series User’s Manual (Field Network) -This chapter describes the overview, setting method, data allocation, and operating procedure of the dat

Strona 67

4- IV Series User’s Manual (Field Network) -Precautions on Regulations and StandardsFor IV-500C/IV-500CA/IV-500M/IV-500MA/IV-150M/IV-150MA/ IV-2000M/I

Strona 68

5-2- IV Series User’s Manual (Field Network) -Overview of the data I/O communicationOverview of the data I/O communicationWhat is data I/O communicati

Strona 69

5-3- IV Series User’s Manual (Field Network) -Data I/O communication setting methodThis following explains the setting method when using the data I/O

Strona 70

5-4- IV Series User’s Manual (Field Network) -Data I/O communication setting methodWhen setting by IV-Navigator (IV-H1)Set the eld network settings o

Strona 71

5-5- IV Series User’s Manual (Field Network) -Data I/O communication setting methodSetting the device name Device naming rules for when the PROFINET

Strona 72

5-6- IV Series User’s Manual (Field Network) -Data I/O communication setting methodPLC settingsYou can set the following settings for the PLC: (1) Est

Strona 73

5-7- IV Series User’s Manual (Field Network) -Data I/O communication setting methodSetting the Siemens TIA PortalThis following explains the setting m

Strona 74 - Command Control

5-8- IV Series User’s Manual (Field Network) -Data I/O communication setting method6 Install the GSDML le if you are conguring the IV series for the

Strona 75 - Device Result Bits

5-9- IV Series User’s Manual (Field Network) -Data I/O communication setting method11 Click the [Properties] tab. Select [PROFINET interface [x1]] -

Strona 76 - Device Statistics

5-10- IV Series User’s Manual (Field Network) -Data I/O communication setting method14 Click the CPU in the [Devices] tab. Select [Download to device]

Strona 77 - Tool Result

5-11- IV Series User’s Manual (Field Network) -Data I/O communication setting methodSetting the Siemens SIMATIC ManagerThis following explains the set

Strona 78

5- IV Series User’s Manual (Field Network) -Version of the IV SeriesYou can download the most recent operation software for the sensor (IV-150/500/200

Strona 79

5-12- IV Series User’s Manual (Field Network) -Data I/O communication setting method7 Set the IP address and subnet mask of the CPU, and then click th

Strona 80

5-13- IV Series User’s Manual (Field Network) -Data I/O communication setting method11 Open [PROFINET IO] - [Additional Field Devices] - [Sensors] -

Strona 81

5-14- IV Series User’s Manual (Field Network) -Data I/O communication setting method17 Select [Station] - [Save and Compile] in the [HW Cong] window

Strona 82

5-15- IV Series User’s Manual (Field Network) -Data I/O communication setting methodMEMO5Data I/O communication

Strona 83

5-16- IV Series User’s Manual (Field Network) -Data allocations in the data I/O communicationThe PROFINET communication for the IV series is dened us

Strona 84

5-17- IV Series User’s Manual (Field Network) -Data allocations in the data I/O communicationStatus Modules (IV series → PLC)Status Modules are module

Strona 85

5-18- IV Series User’s Manual (Field Network) -Data allocations in the data I/O communicationDevice Status WordsSlot No.: 4Module size: 16 bytesAddr

Strona 86

5-19- IV Series User’s Manual (Field Network) -Data allocations in the data I/O communicationTool Result Modules (IV series→ PLC)Tool Result Modules a

Strona 87

5-20- IV Series User’s Manual (Field Network) -Data allocations in the data I/O communicationControl Modules parameter detailsCommand Control Addres

Strona 88

5-21- IV Series User’s Manual (Field Network) -Data allocations in the data I/O communicationCommand Control Address 2 to 3: Handshake controlThe Bi

Strona 89

6- IV Series User’s Manual (Field Network) -Version of the IV SeriesIV-Navigator (IV-H1)Version DescriptionR1.00.00 The initial version.R1.01.00 Compa

Strona 90 - [Disabled])

5-22- IV Series User’s Manual (Field Network) -Data allocations in the data I/O communicationStatus Modules parameter detailsCommand Status Bits Add

Strona 91

5-23- IV Series User’s Manual (Field Network) -Data allocations in the data I/O communicationCommand Status Bits Address 2 to 3: Handshake control/s

Strona 92 - [Enabled])

5-24- IV Series User’s Manual (Field Network) -Data allocations in the data I/O communication By monitoring whether the unit is in “Imaging” status,

Strona 93

5-25- IV Series User’s Manual (Field Network) -Data allocations in the data I/O communicationDevice Results Bits Address 0 to 3: Status resultThe Bi

Strona 94

5-26- IV Series User’s Manual (Field Network) -Data allocations in the data I/O communicationzDevice Status Words Address 0 to 15: Error/status/statu

Strona 95

5-27- IV Series User’s Manual (Field Network) -Data allocations in the data I/O communicationDevice Statistics Address 0 to 27 (Statistics informati

Strona 96 - Handshake control [Disabled]

5-28- IV Series User’s Manual (Field Network) -Data allocations in the data I/O communicationTool Result Modules parameter detailsPosition Adjust Re

Strona 97

5-29- IV Series User’s Manual (Field Network) -Data allocations in the data I/O communicationError code listThe following shows the list of error code

Strona 98

5-30- IV Series User’s Manual (Field Network) -Data allocations in the data I/O communicationWarning code listThe following shows the list of warning

Strona 99

5-31- IV Series User’s Manual (Field Network) -Data allocations in the data I/O communicationWarning codeContent Cause Countermeasure70FTP Transfer Er

Strona 100 - Program switching

7- IV Series User’s Manual (Field Network) -Structure of This Manual1Getting StartedThis chapter explains the system congurations and overview of IV

Strona 101 - Rockwell Automation PLC

5-32- IV Series User’s Manual (Field Network) -Operating procedure of the data I/O communicationOperating procedure of the data I/O communicationThis

Strona 102 - Reference program (PROFINET)

5-33- IV Series User’s Manual (Field Network) -Operating procedure of the data I/O communicationWhen a trigger is unsuccessfulTrigger requestResult

Strona 103 - Handshake control [Enabled]

5-34- IV Series User’s Manual (Field Network) -Operating procedure of the data I/O communicationReading out the overall status result of the IV series

Strona 104

5-35- IV Series User’s Manual (Field Network) -Operating procedure of the data I/O communicationSwitching the programs in the IV seriesProgram No.Prog

Strona 105

5-36- IV Series User’s Manual (Field Network) -Operating procedure of the data I/O communicationRegistering a master image for the IV series externall

Strona 106

A-1- IV Series User’s Manual (Field Network) -Reference program (EtherNet/IP) ...A-2Reference program (PROFINET) ...

Strona 107

A-2- IV Series User’s Manual (Field Network) -Reference program (EtherNet/IP)This section introduces a reference program for when using EtherNet/IP co

Strona 108 - Revision history

A-3- IV Series User’s Manual (Field Network) -Reference program (EtherNet/IP)Rockwell Automation PLCRung0Rung1REQONSONSONSTrigger Ack TriggerComplete

Strona 109 - WARRANTIES AND DISCLAIMERS

A-4- IV Series User’s Manual (Field Network) -Reference program (EtherNet/IP)Handshake control [Enabled]Keyence KV seriesLine 1Line 2Line 3Line 4Line

Strona 110 - 244008E 1044-3 256GB

A-5- IV Series User’s Manual (Field Network) -Reference program (EtherNet/IP)Rockwell Automation PLCRung0Rung1Rung2REQONSONSONSTrigger AckResult Ready