3-2 I/O Communication
3-14
- DeviceNet Compatible Network Unit DL-DN1 User’s Manual (GT2) -
3
Communicating with the GT2 series
Rewrite setting value
Sensor amplifier ID numbers 01 to 15 are assigned to bits 0 to 14, respectively.
For details of communication methods, see "Rewriting a Setting Value of a Sensor
Amplifier" (page 3-20).
3-output mode
OUT area
m: The first device number assigned to the DL-DN1
IN area
n: The first device number assigned to the DL-DN1
The device assignments are the same for all 3-output modes including extended
modes.
Device
(DEC)
Name
Bit 7 Bit 6 ... Bit 1 Bit 0
Bit 15 Bit 14 ... Bit 9 Bit 8
m+3
Request to rewrite HIGH
setting
ID08 ID07 ... ID02 ID01
Reserved ID15 ... ID10 ID09
m+4 to 5
HIGH setting
High setting to be rewritten (4-byte signed integer)
m+6
Request to rewrite LOW
setting
ID08 ID07 ... ID02 ID01
Reserved ID15 ... ID10 ID09
m+7 to 8
LOW setting
Low setting to be rewritten (4-byte signed integer)
m+9
Request to rewrite PRESET
setting
ID08 ID07 ... ID02 ID01
Reserved ID15 ... ID10 ID09
m+10 to 11 PRESET
setting
PRESET setting to be rewritten (4-byte signed integer)
Device
(DEC)
Name
Bit 7 Bit 6 ··· Bit 1 Bit 0
Bit 15 Bit 14 ··· Bit 9 Bit 8
n+7 Setting-value rewrite error
ID08 ID07 ··· ID02 ID01
Reserved ID15 ··· ID10 ID09
n+8
HIGH setting rewrite
complete
ID08 ID07 ··· ID02 ID01
Reserved ID15 ··· ID10 ID09
n+9
LOW setting rewrite
complete
ID08 ID07 ··· ID02 ID01
Reserved ID15 ··· ID10 ID09
n+10
PRESET setting rewrite
complete
ID08 ID07 ··· ID02 ID01
Reserved ID15 ··· ID10 ID09