2-2 Wiring
2-6
- DeviceNet Compatible Network Unit DL-DN1 User’s Manual (SK-1000) -
2
Connection and Configuration
2
Install a shrinkable tube.
Cover the exposed sheathed conductors and the sheath using a shrinkable
tube approximately 40 mm long.
3
Strip the sheathed conductors.
Strip approximately 10 mm of sheath from the end of each conductor.
If you are using solderless terminals, perform cable wiring/
trimming appropriately to suit the specifications of the partic-
ular terminals.
Recommended solderless terminals: Phoenix Contact's A/AI
Series
Do not perform soldering (pre-soldering) on the trimmed end
of the cable.
Approx. 40mm
Shrinkable tube
Sheath
Approx. 10mm
Sheathed conductor
Point