Communication Response Time
Time Frames of Communication Response Time
This section describes the communication time frames (T2 to T6).
The maximum time required is shown for each time frame. However, depending on the
actual environment, it may require more time.
T2 (DL-RS1A data processing time)
T3 (Command send time from external device)
Refer to the manual supplied with the external device connected to DL-RS1A.
Reference
Number of connected
sensor amplifiers
Data processing time (T2)
SK-1000 Series
19 ms
211 ms
314 ms
418 ms
520 ms
624 ms
727 ms
831 ms
Communication Response Time
T4 (DL-RS1A command processing time)
The processing time varies according to the command sent from the external device.
z Read commands
z Write commands
Communication command
Number of connected
sensor amplifiers
Command processing time (T4)
SK-1000 Series
SR
113 ms
214 ms
316 ms
418 ms
519 ms
621 ms
722 ms
824 ms
M0/MS/DRQ input
1 to 8
4 ms
Communication command
Number of connected
sensor amplifiers
Command processing time (T4)
SK-1000 Series
SW
127 ms
232 ms
337 ms
445 ms
550 ms
658 ms
763 ms
871 ms
AW
159 ms
260 ms
361 ms
463 ms
564 ms
666 ms
768 ms
870 ms