Chapter 3 Simulator
2-108
3
3.3.5 Stop/reset and device all clear
To stop/reset execution of scans or steps, or to clear all the devices, perform the
following procedure.
Stopping/pausing the operations
Execute
Stop (Shift + F5)
Pause (F4)
Operations can be stopped or paused.
Select "Stop" or "Pause" from the "Execute" menu, or click the
or button.
When "Stop" is specified, all types of operations are stopped and the output Y is
cleared.
When "Pause" is specified, all types of operations are temporarily stopped.
Note: When operations are stopped, execution of a step in the reverse direction is
not available. To execute a step in the reverse direction after stopping operations,
you must execute the steps again. When operations are paused, execution of a step
in the reverse direction can be performed.
Reset
Execute
Reset (F10)
The current value can be returned to the default value.
Select "Reset" from the "Execute" menu, or click the
button.
When this procedure is performed during operation, the operation is stopped.
The system is processed as if the power of the PLC is turned off, and is then
turned on again.
Device all clear
Execute
Device All Clear
DM All Clear
Latching Relay All Clear
Counter All Clear
By the device all clear function, the current value of some devices can be initialized.
The following three initialization methods are available.
Clearing all data memory
Execute Device All Clear DM All Clear
Clearing all latching relays
Execute Device All Clear Latching Relay All Clear
Clearing all counters
Execute Device All Clear Counter All Clear
When device all clear is performed during operation, the operation is stopped.