High-speed, High-accuracy
CCD Laser Displacement Sensor
LK-G Series
User’s Manual
Read this manual before using the system in order
to achieve maximum performance.
Keep this manual in a safe place for future
reference.
High-speed, High-accuracy CCD Laser Displacement Sensor
LK-G Series User’s Manual
96M1573
0
KEYENCE ITALIA S.p.A.
Phone: 02-6688220 Fax: 02-66825099
KEYENCE SINGAPORE PTE LTD.
Phone: 6392-1011 Fax: 6392-5055
AFFILIATED COMPANIES
KEYENCE CORPORATION OF AMERICA
Phone: 201-930-0100 Fax: 201-930-0099
KEYENCE DEUTSCHLAND GmbH
Phone: 06102-36 89-0 Fax: 06102-36 89-10
KEYENCE (UK) LIMITED
Phone: 01908-696900 Fax: 01908-696777
KEYENCE FRANCE S.A.
Phone: 01 56 37 78 00 Fax: 01 56 37 78 01
KEYENCE (MALAYSIA) SDN BHD
Phone: 03-2092-2211 Fax: 03-2092-2131
KEYENCE (THAILAND) CO., LTD.
Phone: 02-369-2777 Fax: 02-369-2775
KOREA KEYENCE CO., LTD.
KEYENCE TAIWAN CO., LTD.
Phone: 02-
2718-8700
Fax: 02-
2718-8711
KEYENCE (HONG KONG) CO., LTD.
Phone: 3104-1010 Fax: 3104-1080
KEYENCE INTERNATIONAL TRADING
(SHANGHAI) CO., LTD.
Phone: 021-68757500 Fax: 021-68757550
Phone: 02-563-1270 Fax: 02-563-1271
Specifications are subject to change without notice.
KEYENCE CORPORATION
1-3-14, Higashi-Nakajima,
Higashi-Yodogawa-ku, Osaka,
533-8555, Japan
Phone: 81-6-6379-2211
Fax: 81-6-6379-2131
© KEYENCE CORPORATION, E LK-G-IM 0056-2 96M1573 Printed in Japan
LK-G-M-F-E.fm 1 ページ 2006年5月11日 木曜日 午前11時16分
Przeglądanie stron 0
1 2 3 4 5 6 ... 197 198

Podsumowanie treści

Strona 1 - LK-G Series

High-speed, High-accuracy CCD Laser Displacement Sensor LK-G Series User’s Manual Read this manual before using the system in orderto achieve maximu

Strona 2

8LK-G-M-NO0-E Cautions on Class 2222/ 2 laser productsObserve the following instructions. Otherwise, injury to the human body (eyes and skin) may res

Strona 3 - Safety Precautions

3-423LK-G-M-NO3-E3 Function SettingsSetting the Output Form of the Tolerance ComparatorThe output form of the tolerance comparator can be set. The f

Strona 4

3-433LK-G-M-NO3-E3 Function SettingsSetting the Strobe Output TimeThe period of time for the strobe output to turn ON (one-shot output time) can be s

Strona 5 - Precautions on CE Marking

3-443LK-G-M-NO3-E3 Function SettingsAccumulating the Measurement Value in the Memory (Data Storage Function)Up to 131072 measurement values of OUT1 a

Strona 6 - Precautions for Wiring

3-453LK-G-M-NO3-E3 Function Settings Setting procedure of the method to accumulate data1Hold down the key, and select "oPt on" with the

Strona 7

3-46 3 LK-G-M-NO3-E 3 Function Settings Setting the Operations of the Equipment (Environment Settings) This section describes the operation settings

Strona 8

3-47 3 LK-G-M-NO3-E 3 Function Settings List of Default Values and Setting Ranges The function settings (default) at the time of shipment and the se

Strona 9

3-48 3 LK-G-M-NO3-E 3 Function Settings List of the Environment Setting Screens OUT1HI GO LO TIMHI GO LOOUT2TIM HI GO LOOUT2TIMHI GO LOOUT2TIMHI GO

Strona 10 - LK-G-M-NO0-E

3-49 3LK-G-M-NO3-E3 Function SettingsSetting the Communication Specifications of the RS-232C The communication specifications and the output operation

Strona 11

3-50 3 LK-G-M-NO3-E 3 Function Settings Setting the Program Switching Method Whether the program No. is switched from the display panel or from the

Strona 12 - ■ Label contents

3-513LK-G-M-NO3-E3 Function SettingsCopying/Initializing the ProgramCopying and initializing of the program are performed. Copying procedure of the

Strona 13

9LK-G-M-NO0-EThe LK-G Series is equipped with the following safety features based on IEC60825-1 and CDRH Part 1040.10 (Safety of laser products). La

Strona 14 - ■ Label attachment locations

3-523LK-G-M-NO3-E3 Function Settings5Press the key, and specify the program No. of the copy destination with the key.Program No. 2 is specified as

Strona 15 - Organization of this Manual

3-53 3 LK-G-M-NO3-E 3 Function Settings Preventing Erroneous Operation on the Panel (Panel Lock) This function is used to prohibit operations on th

Strona 16

3-543LK-G-M-NO3-E3 Function SettingsReducing the Power Consumption (Eco Mode)The power consumption can be reduced by turning off the display on the c

Strona 17 - Table of Contents

4-1 LK-G-M-NO4-E4Input/Output Terminals4 This chapter describes the specifications of the input/output terminals and timing chart.Identifying N

Strona 18 - ...3-32

4-24LK-G-M-NO4-E4 Input/Output TerminalsIdentifying Names and Functions of the Input/Output TerminalsThis section describes the names and functions o

Strona 19

4-34LK-G-M-NO4-E4 Input/Output TerminalsCaution• Precautions for WiringPart of each input/output circuit of the LK-G Series is internally common. Be

Strona 20

4-44LK-G-M-NO4-E4 Input/Output Terminals6-pin I/O terminal blockUsed for the analog monitor output.Matching cable specification: AWG28 to 16, Approxim

Strona 21 - Before Use1

4-54LK-G-M-NO4-E4 Input/Output TerminalsExpansion ConnectorUsed for the comparator output, control output, and binary output.Matching connector: FX2B

Strona 22 - System Configuration

4-64LK-G-M-NO4-E4 Input/Output Terminals* COMs for output of pin Nos. 5 and 36 are common.* COMs for input of pin Nos. 12 and 40 are common.* The cor

Strona 23 - Checking the Package Contents

4-74LK-G-M-NO4-E4 Input/Output TerminalsFunctions of the Input and Output SignalsThe following table shows a list of program numbers and how they rel

Strona 24 - LK-GD500: 1 : 1

10LK-G-M-NO0-E Warning labelsThe contents of warning indications and locations for attaching warning labels are described below. The FDA (CDRH) war

Strona 25 - LK-GC2/GC5/GC10/GC20/GC30

4-84LK-G-M-NO4-E4 Input/Output TerminalsThe following table shows a list of program numbers and how they relate to the status of terminals P1 through

Strona 26 - Controller

4-94LK-G-M-NO4-E4 Input/Output TerminalsHow to read the binary outputThe LK-G Series outputs the measurement value as a binary number (two’s compleme

Strona 27 - Terminal panel

4-104LK-G-M-NO4-E4 Input/Output TerminalsElectrical specifications for NPN typeCautionRefer to "Precautions for Wiring" page 4 before wiring

Strona 28

4-114LK-G-M-NO4-E4 Input/Output TerminalsElectrical specifications for PNP typeCautionRefer to "Precautions for Wiring" page 4 before wiring

Strona 29 - Installing the Head

4-124LK-G-M-NO4-E4 Input/Output TerminalsElectrical specifications common to NPN type and PNP type Analog voltage output / analog current outputVoltag

Strona 30 - Reference

4-134LK-G-M-NO4-E4 Input/Output TerminalsTiming ChartThis section describes the timing of the input and output signals.Normal• The minimum input time

Strona 31

4-144LK-G-M-NO4-E4 Input/Output TerminalsPeak hold/bottom/peak-to-peak hold/average hold/sample hold (trigger 1)• The minimum input time (T1), input

Strona 32

4-154LK-G-M-NO4-E4 Input/Output TerminalsSample hold (trigger 2)• The measurement value is determined after the sampling period (T4) has elapsed by u

Strona 33

4-164LK-G-M-NO4-E4 Input/Output TerminalsBinary output• OUT1 and OUT2 are updated asynchronously depending on the filter settings or the options speci

Strona 34

4-174LK-G-M-NO4-E4 Input/Output TerminalsLASER REMOTE/LASER OFF*T6 is a sampling rate. ( page 3-39)T2 is the input response time.( page 4-17)The alar

Strona 35

11LK-G-M-NO0-E● LK-G37/LK-G32/LK-G87/LK-G82/LK-G157/LK-G152/LK-G407/LK-G402/LK-G507/LK-G502● LK-G15/LK-G10FDA (CDRH) IEC (English)IEC (German) IEC (Fr

Strona 36 - LK-G35 LK-G35

4-184LK-G-M-NO4-E4 Input/Output TerminalsTiming details Minimum input time (T1) and input response time (T2)The sampling rate can be changed accordin

Strona 37 - Installing the Controller

5-1 LK-G-M-NO5-E5RS-232C5 This chapter describes how to connect external devices and the com-munication functions for external operation.Speci

Strona 38

5-25LK-G-M-NO5-E5 RS-232CSpecificationsPin LayoutMatching connector specifications: Modular 6-pin plug connector* Do not use the unused terminal. Doin

Strona 39

5-35LK-G-M-NO5-E5 RS-232CCommunication Performance and Communication Mode in the Measurement StateComplete the series of input or output of commands

Strona 40

5-45LK-G-M-NO5-E5 RS-232COutputting Measurement Values and Changing Settings through CommandsYou can import the measurement value or change the param

Strona 41

5-55LK-G-M-NO5-E5 RS-232COutline of the command formatThe LK-G Series controls the incoming command that has been received and sends backthe response

Strona 42

5-65LK-G-M-NO5-E5 RS-232CMeasurement value format ( )The measurement value is outputted in the given format as shown below.The example of the format

Strona 43

5-75LK-G-M-NO5-E5 RS-232CMode Change CommandThis section describes the command format to switch between the "Normal mode" and"Communic

Strona 44 - Switching Modes

5-85LK-G-M-NO5-E5 RS-232CMeasurement Control Command FormatThis section describes the command format to control the measurement such as incomingcomma

Strona 45 - Setting Mode

5-95LK-G-M-NO5-E5 RS-232CCommand detailsThis section describes the details of the incoming commands and the responses that aresent when the incoming

Strona 46 - Default Settings

12LK-G-M-NO0-E Label attachment locations● LK-G35/LK-G30/LK-G37/LK-G32LK-G85/LK-G80/LK-G87/LK-G82● LK-G155/LK-G150/LK-G157/LK-G152LK-G405/LK-G400/L

Strona 47 - LK-G-M-NO2-E

5-105LK-G-M-NO5-E5 RS-232C Auto-zero ON/OFFSets/cancels the Auto-zero function. Auto-zero ON is valid even when the auto-zero is ON, and the refere

Strona 48

5-115LK-G-M-NO5-E5 RS-232C Program● Program No. change● Program No. checkIncoming commandResponse commandCRP W , o CRP W Program No.0 to 7Incomi

Strona 49

5-125LK-G-M-NO5-E5 RS-232C Data storage● Starting the data storage● Initializing the data storage● Stopping the data storage● Outputting the data st

Strona 50

5-135LK-G-M-NO5-E5 RS-232CChange Parameter CommandThese commands are accepted only when the controller is in the "Communication mode".NoteI

Strona 51 - Hysteresis

5-145LK-G-M-NO5-E5 RS-232CCommand detailsThis section describes the details of the incoming commands and the response com-mands that are sent when th

Strona 52

5-155LK-G-M-NO5-E5 RS-232C ABLESets ABLE. ABLE control rangeSets the control range of ABLE.Incoming commandResponse commandSAHW,SW , H A , M , h ,

Strona 53

5-165LK-G-M-NO5-E5 RS-232C Calculation method* Even when specifying a value from 0 to 3 for the calculation method, specify dummy data for the calcu

Strona 54 - HI GO LO TIM

5-175LK-G-M-NO5-E5 RS-232C Scaling FilterIncoming commandResponse commandSBOW,SW , O B ,y, f f f f f f f , f f f f f f f ,f f f f f f f ,CRf f f f

Strona 55 - Switching Program Nos

5-185LK-G-M-NO5-E5 RS-232C Trigger mode Offset Analog output scaling* Set the voltage value in mV for the setting value format of the output value

Strona 56

5-195LK-G-M-NO5-E5 RS-232C Measurement mode, minimum display unit, and analog-through Data storage Sampling rate, mutual interference prevention,

Strona 57

13LK-G-M-NO0-E456Before UseOperations and Functions during Measurement Input/Output TerminalsFunction SettingsRS-232CSpecificationsAppendicesChapter 1

Strona 58

5-205LK-G-M-NO5-E5 RS-232CCheck Parameter Command FormatThis section describes the format of the command to check the setting contents.These commands

Strona 59 - Function Settings3

5-215LK-G-M-NO5-E5 RS-232CTiming ChartThe timing chart of the incoming/response command is shown below.The t-time is identified as follows. [ms]* The

Strona 60

5-225LK-G-M-NO5-E5 RS-232COutputting Measurement Values in Exter-nal SynchronizationThis section describes how to synchronize the measurement value w

Strona 61 - Setting the Head

5-235LK-G-M-NO5-E5 RS-232CTiming Chart When the measurement mode is other than sample hold (trigger 2)• When the measurement mode is set to normal,

Strona 62 - Mounting mode

5-245LK-G-M-NO5-E5 RS-232COutput FormatThe command format of the measurement value output is identified as follows.Regardless of the setting of the ti

Strona 63 - Setting ABLE

6-1 LK-G-M-NO6-E6Specifications of the LK-G Series6 This chapter describes the specifications of the controller and the head, outside dimensions

Strona 64 - A-1" with the

6-26LK-G-M-NO6-E6 Specifications of the LK-G SeriesSpecificationsSpecifications of the ControllerModel Single unit type LK-G3001V LK-G3001PVSeparate ty

Strona 65

6-36LK-G-M-NO6-E6 Specifications of the LK-G Series*1 The LK-G3001 can be used independently. The measurement value display and the settingchange can

Strona 66

6-46LK-G-M-NO6-E6 Specifications of the LK-G SeriesSpecifications of the Head LK-G15/LK-G10*1 When the sampling rate is 20 µs, the value becomes +0.3

Strona 67

6-56LK-G-M-NO6-E6 Specifications of the LK-G Series LK-G35/LK-G30*1 When the sampling rate is 20 µs, the value becomes +1.8 (FAR side) to –5 mm (NEA

Strona 68

14LK-G-M-NO0-E

Strona 69

6-66LK-G-M-NO6-E6 Specifications of the LK-G Series LK-G37/LK-G32*1 When the sampling rate is 20 µs, the value becomes +1.8 (FAR side) to –5 mm (NEA

Strona 70 - Setting the Mounting Mode

6-76LK-G-M-NO6-E6 Specifications of the LK-G Series LK-G85/LK-G80*1 The value when measuring the KEYENCE standard target (ceramic). When the samplin

Strona 71

6-86LK-G-M-NO6-E6 Specifications of the LK-G Series LK-G87/LK-G82*1 The value when measuring the KEYENCE standard target (ceramic). When the samplin

Strona 72

6-96LK-G-M-NO6-E6 Specifications of the LK-G Series LK-G155/LK-G150*1 The value when measuring the KEYENCE standard target (ceramic). When the sampl

Strona 73 - -99.9999 to +99.9999 0.0000

6-106LK-G-M-NO6-E6 Specifications of the LK-G Series LK-G157/LK-G152*1 The value when measuring the KEYENCE standard target (ceramic). When the samp

Strona 74 - Transparent object A/B

6-116LK-G-M-NO6-E6 Specifications of the LK-G Series LK-G405/LK-G400*1 The value when measuring the KEYENCE standard target (ceramic) in the standar

Strona 75 - Minimum display unit

6-126LK-G-M-NO6-E6 Specifications of the LK-G Series LK-G407/LK-G402*1 The value when measuring the KEYENCE standard target (ceramic) in the standar

Strona 76 - Calculating Between the Heads

6-136LK-G-M-NO6-E6 Specifications of the LK-G Series LK-G505/LK-G500*1The value when measuring the KEYENCE standard target (ceramic) in the standard

Strona 77

6-146LK-G-M-NO6-E6 Specifications of the LK-G Series LK-G507/LK-G502*1The value when measuring the KEYENCE standard target (ceramic) in the standard

Strona 78

6-156LK-G-M-NO6-E6 Specifications of the LK-G SeriesSpecifications of the Head-to-Controller CableStatus TableModel LK-GC2 LK-GC5 LK-GC10 LK-GC20 LK-G

Strona 79

14LK-G-M-NO0-ETable of ContentsSafety Precautions ... 1General Cautions... 1WARNING ...

Strona 80 - [-2 kPF

6-166LK-G-M-NO6-E6 Specifications of the LK-G Series* ON/OFF indicates the ON/OFF status of the NPN or PNP open-collector output.* Valid/Invalid indi

Strona 81

6-176LK-G-M-NO6-E6 Specifications of the LK-G SeriesResponse Delay Time Measurement response timeThis is the period of time until the unit recognize

Strona 82

6-186LK-G-M-NO6-E6 Specifications of the LK-G SeriesLK-G3001/LK-G3001PLK-GD500 Panel cutout4-M4 screw, depth:6DIN railmounting portion662(65) 9513.57

Strona 83 - Sample-and

6-196LK-G-M-NO6-E6 Specifications of the LK-G Series Head• LK-G15/LK-G10• LK-G35/LK-G30• LK-G37/LK-G324350026.35451.215Reference level27 11.59 to 11

Strona 84

6-206LK-G-M-NO6-E6 Specifications of the LK-G Series• LK-G85/LK-G80/LK-G87/LK-G82At reference distanceInstallation hole2-ø4.5100.425.514.590.665.49.3

Strona 85

6-216LK-G-M-NO6-E6 Specifications of the LK-G Series• LK-G155/LK-G150At reference distance1833.382.24350076.2108.5 to 186.5110 to 190686.867.3420.28.

Strona 86

6-226LK-G-M-NO6-E6 Specifications of the LK-G Series• LK-G405/LK-G400/LK-G407/LK-G40220108 1854.5768.219.236.2500430ø7ø12.675.7691.96.820.1111.310.2°

Strona 87

6-236LK-G-M-NO6-E6 Specifications of the LK-G Series• LK-G505/LK-G500/LK-G507/LK-G50220108 1854.5768.219.236.243500ø7ø12.675.7691.96.820.1111.310.2°1

Strona 88

6-246LK-G-M-NO6-E6 Specifications of the LK-G Series Controller-to-head cableLK-GC2/LK-GC5/LK-GC10/LK-GC20/LK-GC3011.5ø6.6Cable length (2m,5m,10m,20

Strona 89

6-256LK-G-M-NO6-E6 Specifications of the LK-G SeriesCharacteristicsSpot Dimension LK-G15 LK-G10 LK-G35/LK-G37 LK-G30/LK-G32 LK-G85/LK-G87 LK

Strona 90 - Measuring with Offset

15LK-G-M-NO0-EList of Functions and Function Nos..3-13List of Default Values and Setting Ranges ...3-15List of

Strona 91

6-266LK-G-M-NO6-E6 Specifications of the LK-G Series LK-G155/LK-G157 LK-G150/LK-G152 LK-G405/LK-G407 LK-G400/LK-G402 LK-G505/LK-G507 LK-G500

Strona 92 - Scaling the Analog Output

6-276LK-G-M-NO6-E6 Specifications of the LK-G SeriesMutual InterferenceNo interference occurs if the beam spot of another sensor is out of the shaded

Strona 93 - " with the

6-286LK-G-M-NO6-E6 Specifications of the LK-G Series LK-G155/LK-G150 LK-G405/LK-G400/LK-G407/LK-G40227mm7mm5mm 5mm44mm92mm192mmLK-G15529mm6mm41mm29

Strona 94

6-296LK-G-M-NO6-E6 Specifications of the LK-G Series LK-G505/LK-G500/LK-G507/LK-G50258mm9mm227mm245mm7mm1005mmLK-G5008mm 8mm

Strona 95 - Setting the Common Function

6 Specifications of the LK-G Series6-306LK-G-M-NO6-EMEMO

Strona 96

A-1 LK-G-M-NOA-EAppendices7 Troubleshooting ... A-2Error Messages ...

Strona 97

A-2 LK-G-M-NOA-E Troubleshooting This section describes the possible problems and their solutions for LK-G Series operation.Symptom Checking content

Strona 98

A-3 LK-G-M-NOA-E Displayed measurement values fluctuate.Is the number of times for averaging properly set?Set the number of times for averaging proper

Strona 99

A-4 LK-G-M-NOA-E Analog output cannot be outputted properly.Is the unit properly wired? Check the wiring and connect properly. Does the voltage excee

Strona 100 - LK-G-M-NO3-E

A-5 LK-G-M-NOA-E Error Messages The list of error messages displayed in the LK-G Series and their remedies is shown below.* If you cannot resume the

Strona 101

16LK-G-M-NO0-EOutput... 5-22Timing Chart ... 5-23Output Format...

Strona 102

A-6 LK-G-M-NOA-E List of Optional Products These are the optional products supported by the LK-G Series.Name Model Appearance DescriptionND filter LK-

Strona 103

A-7 LK-G-M-NOA-E RS-232C cable OP-96368 The communication cable for RS-232C (2.5 m)Conversion adaptor for RS-232COP-26401 Conversion adaptor for the

Strona 104 - (Environment Settings)

A-8LK-G-M-NOA-EIndexAlpha-numerical 12-pin I/O terminal block... 1-7, 4-26-pin I/O terminal block... 1-7, 4-4AABLE calibrati

Strona 105

A-9LK-G-M-NOA-EGGO ... 2-3HHead ... 1-4Head con

Strona 106

A-10LK-G-M-NOA-EOutput Format ...5-24PPackage Contents...1-3Panel lock...

Strona 107

A-11MEMOLK-G-M-NOA-E

Strona 108

Date of printingMarch, 2006May, 2006October, 2006September, 2007Official releaseSecond editionThird editionFourth editionVersion Revision contentsRevi

Strona 109

Introduction This Instruction Manual describes the basic operations and hardware functions of the LK-G Series. Read this manual carefully to ensure

Strona 110

High-speed, High-accuracy CCD Laser Displacement Sensor LK-G Series User’s Manual Read this manual before using the system in orderto achieve maximu

Strona 111

Introduction This Instruction Manual describes the basic operations and hardware functions of the LK-G Series. Read this manual carefully to ensure

Strona 113 - Input/Output Terminals4

1-1LK-G-M-NO1-E1Before Use1 This chapter describes the configuration of the LK-G Series, cautions and required preparation before use. Be sure to read

Strona 114 - Input/Output Terminals

1-21LK-G-M-NO1-E1 Before UseSystem ConfigurationThe LK-G Series can be used for various purposes in combination with commercially available devices.*1

Strona 115 - LK-G-M-NO4-E

1-31LK-G-M-NO1-E1 Before UseChecking the Package ContentsThe LK-G Series consists of the following models. Check if the parts and equipment listed be

Strona 116 - 6-pin I/O terminal block

1-41LK-G-M-NO1-E1 Before UseLK-GD500 (Separate Type Controller)Display panel Panel attachment ring LK-GD500: 1 : 1Head (LK-G15/LK-G10)Head: 1Head (Mo

Strona 117 - Expansion Connector

1-51LK-G-M-NO1-E1 Before UseLK-GC2/GC5/GC10/GC20/GC30Head-to-controller cable: 1LK-GC2 : 2-m cableLK-GC5 : 5-m cableLK-GC10 : 10-m cableLK-GC20 : 20-

Strona 118

1-61LK-G-M-NO1-E1 Before UseIdentifying Part Names and FunctionsThis section describes the name and function of each part.ControllerDisplay panel1 Di

Strona 119

1-71LK-G-M-NO1-E1 Before UseOperation keysTerminal panel1 RS-232C connectorEstablishes communication with a PC or a PLC.2 USB connectorUsed when conn

Strona 120 - NPN type PNP type

1-81LK-G-M-NO1-E1 Before UseHead1 Sensor (emitter)Emits the laser beam for measurement. Itis protected with a glass cover.2 Sensor (receiver)Receives

Strona 121

1-91LK-G-M-NO1-E1 Before UseInstalling and Connecting the Heads and Optional PartsInstalling the HeadAdjust the distance between the head and the mea

Strona 122 - ■ NPN open-collector output

1LK-G-M-NO0-ESafety PrecautionsGeneral Cautions• At startup and during operation, be sure to monitor the functions and performance ofthe LK-G Series.

Strona 123 - Short-circuit current (Typ.)

1-101LK-G-M-NO1-E1 Before Use LK-G35/LK-G30/LK-G37/LK-G32The measurement range is shown in the figure below.* The value inside the parentheses ( ) is

Strona 124 - Output impedance

1-111LK-G-M-NO1-E1 Before Use LK-G85/LK-G80/LK-G87/LK-G82The measurement range is shown in the figure below.* The value inside the parentheses ( ) is

Strona 125 - Timing Chart

1-121LK-G-M-NO1-E1 Before Use LK-G155/LK-G150/LK-G157/LK-G152The measurement range is shown in the figure below.* The value inside the parentheses (

Strona 126

1-131LK-G-M-NO1-E1 Before Use LK-G405/LK-G400/LK-G407/LK-G402The measurement range is shown in the figure below.* The value inside the parentheses (

Strona 127 - Sample hold (trigger 2)

1-141LK-G-M-NO1-E1 Before Use LK-G505/LK-G500/LK-G507/LK-G502The measurement range is shown in the figure below.*1 The value inside the parentheses (

Strona 128 - Binary output

1-151LK-G-M-NO1-E1 Before UseAttaching the ND Filter (Option)If the head is installed for specular reflection and and the measurement target is a shin

Strona 129 - LASER REMOTE/LASER OFF

1-161LK-G-M-NO1-E1 Before UseInstallations Depending on the Measurement TargetMeasuring distanceUse the head as close to the reference distance as po

Strona 130 - Average

1-171LK-G-M-NO1-E1 Before UseInstalling the ControllerInstall the controller to the DIN rail, or fix it with screws.Caution on the orientation of the

Strona 131 - RS-232C5

1-181LK-G-M-NO1-E1 Before UseInstalling the LK-G3001V/LK-G3001PVLK-G3001PV (single unit type controller)Install it on its bottom.Installing the LK-G3

Strona 132 - Specifications

1-191LK-G-M-NO1-E1 Before UseSeparating the single unit type controller1Disconnect the display panel cable from the display panel connector on the co

Strona 133 - LK-G-M-NO5-E

2LK-G-M-NO0-E CAUTIONFollow the safety precautions below to ensure safe operation • Be sure to turn the power off when you plug/unplug the cable th

Strona 134 - Parity check None/Even/Odd

1-201LK-G-M-NO1-E1 Before UseCombining the separate type controller1Install the display panel by aligning it with the two protrusions on the display

Strona 135 - Outline of the command format

1-211LK-G-M-NO1-E1 Before Use4Install the display panel fixing case along the groove on the controller.CAUTIONBe sure to check the orientation of the

Strona 136 - F F F F F F

1-221LK-G-M-NO1-E1 Before UseConnectionCAUTION• Be sure to turn off the power of the controller before connecting/disconnecting cables. Failure to do

Strona 137 - Command list

1-231LK-G-M-NO1-E1 Before Use Connecting the display panelIn the case of the separate type controller, the display panel cable is used for connectin

Strona 138 - Operation Response command

1-241LK-G-M-NO1-E1 Before UseOutline of Measurement and SettingsSwitching ModesThe LK-G has the following modes : * Program switch mode : Switches be

Strona 139 - Command details

1-251LK-G-M-NO1-E1 Before UseSetting ModeIn the Setting mode, every time the key is pressed, the setting content advances in this order : Head Sett

Strona 140 - ● Auto-zero OFF

1-261LK-G-M-NO1-E1 Before UseReturning the LK-Series to the Factory Default SettingsYou can initialize the controller and return the settings to the

Strona 141 - ● Clearing statistics

2-1 LK-G-M-NO2-E 2 Operations and Functions duringMeasurement 2 This chapter describes the operations that can be performed during dis-placement mea

Strona 142

2-2 2 LK-G-M-NO2-E 2 Operations and Functions during Measurement Switching the Measurement Value Displays This section describes how to switch the m

Strona 143 - Analog output

2-3 2 LK-G-M-NO2-E 2 Operations and Functions during Measurement Setting the Tolerance Comparator Value This section describes how to read the toler

Strona 144

3LK-G-M-NO0-EInfluence of dust or dirtThe measurement may fluctuate due to dirt, dust or fluid such as water or oil in the following cases: • Adhesion on

Strona 145

2-4 2 LK-G-M-NO2-E 2 Operations and Functions during Measurement Measurement stops while the setting is in progress. Setting Procedures for toleran

Strona 146

2-52LK-G-M-NO2-E2 Operations and Functions during MeasurementHysteresisIf the measurement value is fluctuating around the tolerance comparator value,

Strona 147

2-62LK-G-M-NO2-E2 Operations and Functions during MeasurementSetting the Display Value Instantaneously to Zero (Auto-Zero)This section describes the

Strona 148 - 0 1 0 000

2-72LK-G-M-NO2-E2 Operations and Functions during Measurement Operations from the display panel1Measure the target to be used as a reference.Assume

Strona 149

2-82LK-G-M-NO2-E2 Operations and Functions during MeasurementProgram FunctionEight Programs can be switched among Program Nos. 0 to 7 in the LK-G Ser

Strona 150

2-92LK-G-M-NO2-E2 Operations and Functions during MeasurementSwitching Program Nos.This section describes the Program No. switch function, which can

Strona 151

2-102LK-G-M-NO2-E2 Operations and Functions during MeasurementPerforming Statistical Computation with the Measurement ValueStatistical computation wi

Strona 152

2-112LK-G-M-NO2-E2 Operations and Functions during Measurement Setting procedures of statistical data1Press the key to change the screen to show t

Strona 153 - TIMING input

2 Operations and Functions during Measurement2-122LK-G-M-NO1-EMEMO

Strona 154

3-1 LK-G-M-NO3-E3Function Settings3 This chapter describes the functions of the LK-G Series and the setting procedures.Measurement, Data Flow

Strona 155 - LK-G-M-NO6-E

4LK-G-M-NO0-E EMI: EN61326, class AEMS: EN61326Length of the power cord that is connected to the Controller, and length of all input/output cords mus

Strona 156

3-23LK-G-M-NO3-E3 Function SettingsMeasurement, Data Flow and FunctionsThe LK-G Series can connect two heads. Each head can perform measurement indiv

Strona 157

3-33LK-G-M-NO3-E3 Function SettingsSetting the HeadThis section describes the settings related to the sensing for stable detection.List of Functions

Strona 158 - Specifications of the Head

3-43LK-G-M-NO3-E3 Function SettingsList of the Head Setting ScreensOUT1HI GO LO TIMHI GO LOOUT2TIM HI GO LOOUT2TIMHI GO LOOUT2TIMHI GO LOOUT2TIMHI GO

Strona 159 - 3a (CDRH)

3-53LK-G-M-NO3-E3 Function SettingsSetting ABLEThe LK-G Series measures the displacement of the target by measuring the laser beam reflected from the

Strona 160 - 2 (CDRH)

3-63LK-G-M-NO3-E3 Function Settings Setting procedure of ABLE (MANUAL)1Hold down the key, and select "kEAd-A" with the key."Head

Strona 161 - ■ LK-G85/LK-G80

3-73LK-G-M-NO3-E3 Function SettingsSetting the Measurement Mode According to the Measuring TargetSpecifying the features of the measuring target stab

Strona 162 - ■ LK-G87/LK-G82

3-83LK-G-M-NO3-E3 Function SettingsSpecifying the Process When Measurement is Not Possible (Alarm Process)The measurement is disabled when measuremen

Strona 163 - ■ LK-G155/LK-G150

3-93LK-G-M-NO3-E3 Function Settings Setting procedure of the alarm process1Hold down the key, and select "kEAd-A" with the key."

Strona 164 - ■ LK-G157/LK-G152

3-103LK-G-M-NO3-E3 Function SettingsAutomatically Teaching the Adjustment Range of ABLE According to the TargetThe ABLE calibration function optimize

Strona 165 - ■ LK-G405/LK-G400

3-113LK-G-M-NO3-E3 Function Settings Setting procedure of the ABLE calibration1Hold down the key, and select "kEAd-A" with the key."

Strona 166 - ■ LK-G407/LK-G402

5LK-G-M-NO0-ELK-G3001PV/LK-G3001P (PNP type)24 VDC (-) and COM IN are common via a choke coil. Also, COM IN of the expansion connector is common via a

Strona 167 - ■ LK-G505/LK-G500

3-123LK-G-M-NO3-E3 Function SettingsSetting the Mounting ModeThe LK-G Series measures the displacement of the target by measuring the reflected laser

Strona 168 - ■ LK-G507/LK-G502

3-133LK-G-M-NO3-E3 Function SettingsSetting the Conditions of the Measure-ment Value OutputThe functions related to data processing are set.List of F

Strona 169 - Status Table

3-143LK-G-M-NO3-E3 Function SettingsFunctions "A" and "(" specify the following sub-functions.* The shaded cells are set by de

Strona 170

3-153LK-G-M-NO3-E3 Function SettingsList of Default Values and Setting RangesFunction Item Settable rangeDefault valueRemarksACalculation method Head

Strona 171 - Unit (mm)

3-163LK-G-M-NO3-E3 Function SettingsList of the OUT Setting ScreensOUT1HI GO LO TIMHI GO LOOUT2TIM HI GO LOOUT2TIMHI GO LOOUT2TIMHI GO LOOUT2TIMHI GO

Strona 172 - LK-GD500 Panel cutout

3-173LK-G-M-NO3-E3 Function SettingsHI GO LOOUT2TIMHI GO LOOUT2TIMHI GO LOOUT2TIMHI GO LOOUT2TIMHI GO LOOUT2TIMHI GO LOOUT2TIMHI GO LOOUT2TIMHI GO LO

Strona 173 - Specular reflection setup

3-183LK-G-M-NO3-E3 Function SettingsCalculating Between the HeadsThe surface displacement, thickness, and height-difference measurements can be perfo

Strona 174

3-193LK-G-M-NO3-E3 Function Settings Setting procedure of the calculation between heads1Hold down the key, and select "oUt-1" with the

Strona 175

3-203LK-G-M-NO3-E3 Function SettingsSetting the Scaling for Measurement (Calibration)The displayed value for the measurement value can be calibrated

Strona 176

3-213LK-G-M-NO3-E3 Function Settings4Press the key to set the input value 1 of the head A, point 1 by using the and keys.The current measurement

Strona 177

6 LK-G-M-NO0-E LK-G3001PV/LK-G3001P (PNP type)Precautions when connecting to computers or other external devices When working in a positive ground

Strona 178

3-223LK-G-M-NO3-E3 Function SettingsStabilizing the Measurement by FilteringThe following three types of function can be set for the filter. Averagin

Strona 179 - Characteristics

3-233LK-G-M-NO3-E3 Function Settings Functions of the low-pass filter and high-pass filterSet the cutoff frequency for each of the filters.The process

Strona 180

3-243LK-G-M-NO3-E3 Function Settings4Press the key, and specify the number of times of mov- ing average with the key. "1024" times i

Strona 181

3-25 3 LK-G-M-NO3-E 3 Function Settings Using the Hold Function (Measurement Mode) This section describes the six types of measurement modes. The f

Strona 182

3-263LK-G-M-NO3-E3 Function Settings Setting procedure of the measurement modeThe setting procedure is described below for the case where peak hold

Strona 183

3-273LK-G-M-NO3-E3 Function SettingsTiming Chart NormalMeasurement is performed consecutively, and the measurement value is displayed and outputted

Strona 184

3-283LK-G-M-NO3-E3 Function Settings Peak hold/bottom hold/peak-to-peak hold/average holdThe values within the period of time (sampling period) dete

Strona 185 - Appendices7

3-293LK-G-M-NO3-E3 Function Settings Sample-and-hold (Trigger 1) • The internal measurement value when the TIMING input becomes ON is retained and o

Strona 186 - Troubleshooting

3-303LK-G-M-NO3-E3 Function Settings Sample-Hold (Trigger 2)• When the TIMING input is turned on, the internal measurement value is retained and out

Strona 187 - LK-G-M-NOA-E

3-313LK-G-M-NO3-E3 Function SettingsSetting the Trigger Condition Trigger 1 and trigger 2 differ in terms of the sampling period during which the mea

Strona 188

7LK-G-M-NO0-ESafety Precautions on Laser ProductsThe models of the LK-G Series are classified in terms of laser class as follows: *LK-G15/LK-G10 is a c

Strona 189 - Error Messages

3-323LK-G-M-NO3-E3 Function SettingsMeasuring with OffsetYou can add or subtract any value to or from the displayed value. When the offset value is s

Strona 190 - List of Optional Products

3-333LK-G-M-NO3-E3 Function SettingsSetting the Unit and the Minimum Display UnitThe display unit and the minimum display unit can be selected from t

Strona 191

3-343LK-G-M-NO3-E3 Function SettingsScaling the Analog Output The analog voltage output can be scaled into the output voltage value within the range

Strona 192

3-353LK-G-M-NO3-E3 Function Settings1Hold down the key, and select "oUt-1" with the key. OUT 1 is set in this example.2Press the key

Strona 193

3-363LK-G-M-NO3-E3 Function SettingsOutputting the Analog Output Without HoldingThe internal measurement value before being retained is outputted whe

Strona 194

3-373LK-G-M-NO3-E3 Function SettingsSetting the Common Function This section describes the functions common to each program No.List of Functions and

Strona 195

3-383LK-G-M-NO3-E3 Function SettingsList of the Common Function Setting ScreensOUT1HI GO LO TIMHI GO LOOUT2TIMHI GO LOOUT2TIM HI GO LOOUT2TIMHI GO LO

Strona 196 - Revision history

3-393LK-G-M-NO3-E3 Function SettingsSetting the Sampling Rate of Measurement Value This section describes how to set the measurement sampling sycle.

Strona 197 - Introduction

3-403LK-G-M-NO3-E3 Function SettingsSetting the Mutual Interference Prevention FunctionWhen two heads are connected and a little distance is left bet

Strona 198

3-413LK-G-M-NO3-E3 Function SettingsSetting the External Timing InputThe control method for the timing inputs of OUT1 and OUT2 can be set. The follo