Keyence Visual KV Series Instrukcja Użytkownika Strona 88

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 87
Chapter 2 System Installation
1-64
2
Visual KV
Series
2.1 Installation Environment
This section describes cautions with the environment in which each unit is installed
and the installation position inside the panel.
2.1.1 Installation Environment
Never install a unit in the following locations:
Locations exposed to direct sunlight
Locations whose ambient temperature is outside the allowable range of 0 to
+50°C
Locations whose ambient humidity is outside the allowable range of 35 to 85%
RH
Locations subject to drastic temperature change where condensation may occur
Locations with corrosive or flammable gases
Locations with excessive dust, salt, iron powder, or soot
Locations subject to direct vibrations and impacts
Locations subject to splashes of water, oil, chemicals, etc.
Locations where a strong magnetic or electrical field is generated
Units are made of synthetic resin. If the unit surface touches a solvent with a
strong dissolving force, it could melt. Keep such solvents away from the units.
2.1 Installation Environment
CAUTION
KVHKA Chap 02.p65 08.3.11, 11:11 AM64
Przeglądanie stron 87
1 2 ... 83 84 85 86 87 88 89 90 91 92 93 ... 443 444

Komentarze do niniejszej Instrukcji

Brak uwag