Keyence FS-N10 Series Instrukcja Użytkownika Strona 1

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Czujniki Keyence FS-N10 Series. KEYENCE FS-N10 Series User Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 0
96141E
Digital Fiber Sensor
FS-N10 Series
User's Manual
Read this manual before use.
Keep this manual in a safe place for future reference.
Przeglądanie stron 0
1 2 3 4 5 6 ... 115 116

Podsumowanie treści

Strona 1 - FS-N10 Series

96141EDigital Fiber SensorFS-N10 SeriesUser's ManualRead this manual before use.Keep this manual in a safe place for future reference.

Strona 2 - Introduction

1Before Using1-2- Digital Fiber Sensor FS-N10 Series User's Manual -1-1Checking the Package ContentsBefore using the unit, make sure that the fol

Strona 3 - Safety Precautions

6Appendix6-2- Digital Fiber Sensor FS-N10 Series User's Manual -6-1TroubleshootingFrequently Asked QuestionsCategory Trouble Cause ActionReceived

Strona 4

6-1 Troubleshooting6Appendix6-3- Digital Fiber Sensor FS-N10 Series User's Manual -Preset relatedA value less than "100.0" is dis-play

Strona 5 - Manual Organization

6-1 Troubleshooting 6Appendix6-4- Digital Fiber Sensor FS-N10 Series User's Manual -OthersInitializing all settings -• Initialize the setting.&q

Strona 6 - Table of Contents

6-1 Troubleshooting6Appendix6-5- Digital Fiber Sensor FS-N10 Series User's Manual -*"ErE" display may remain if the FS-N10 Series is d

Strona 7

6Appendix6-6- Digital Fiber Sensor FS-N10 Series User's Manual -6-2Factory Default Setting (Default Value) ListThe default settings are as follow

Strona 8 - Chapter 6 Appendix

Appendix6-7- Digital Fiber Sensor FS-N10 Series User's Manual -66-3List of Recipe Function SettingsRefer to "Selecting Recipe" (page 3

Strona 9 - Before Using

6-3 List of Recipe Function Settings 6Appendix6-8- Digital Fiber Sensor FS-N10 Series User's Manual -*1 If the recipe r-3/r-4 is loaded with the

Strona 10 - Checking the Package Contents

Appendix6-9- Digital Fiber Sensor FS-N10 Series User's Manual -66-4Restrictions on Each Detection ModeThe sensitivity setting is limited accordin

Strona 11 - Part Names

6-10- Digital Fiber Sensor FS-N10 Series User's Manual -6Appendix6-5IndexThis index provides a list of terms used in this document in alphabetica

Strona 12 - Display/control unit

6-5 Index6-11- Digital Fiber Sensor FS-N10 Series User's Manual -6AppendixRRestrictions on Each Detection Mode...6-9Restrictions for Sensitivity

Strona 13 - Model Number Description

1Before Using1-3- Digital Fiber Sensor FS-N10 Series User's Manual -1-2Part Names*1 Expansion protective cover is installed at the factory prior

Strona 14 - Fiber Units

6-5 Index 6-12- Digital Fiber Sensor FS-N10 Series User's Manual -6AppendixPurpose Description Operation proceduresReference pageSwiching the ou

Strona 15 - Installation and Connection

6-5 Index6-13- Digital Fiber Sensor FS-N10 Series User's Manual -6Appendix* Not available for the FS-N10 Series shipped before March 10, 2011.Lo

Strona 16 - Installing Sensor Amplifiers

6-5 Index 6-14- Digital Fiber Sensor FS-N10 Series User's Manual -6Appendix Basic Settings…(page 4-4)Detection Settings (Func)…(page 4-7)D

Strona 17 - Main unit Expansion unit

6-5 Index6-15- Digital Fiber Sensor FS-N10 Series User's Manual -6Appendix2-output Settings ( )*12…(page 4-35)*1 You can press the button to

Strona 18 - Monitor output

Revision HistoryDate of printing Edition DescriptionSeptember, 2009 First editionOctober, 2009 Second edition Correction of typographical errorsNovemb

Strona 19

WARRANTIES AND DISCLAIMERS(1) KEYENCE warrants the Products to be free of defects in materials and workmanship for a period of one (1) year from the d

Strona 20 - Connecting the Fiber Unit

Copyright (c) 2011 KEYENCE CORPORATION. All rights reserved.009154E 1012-3 96141E Printed in Japan

Strona 21

1-2 Part Names1Before Using1-4- Digital Fiber Sensor FS-N10 Series User's Manual -1-output type (FS-N11/N12/N11C/N12C/N11EN/N12EN/N11MN/N10)

Strona 22

1Before Using1-5- Digital Fiber Sensor FS-N10 Series User's Manual -1-3Model Number DescriptionThe numbers and letters used in product names are

Strona 23 - Basic Operation

1Before Using1-6- Digital Fiber Sensor FS-N10 Series User's Manual -1-4Fiber UnitsThe FS-N10 Series are amplifier units. They must be used in com

Strona 24

22-1- Digital Fiber Sensor FS-N10 Series User's Manual -Installation and ConnectionThis chapter provides procedures for installing sensor amplifi

Strona 25 - 3-1 Quick Reference

2Installation and Connection2-2- Digital Fiber Sensor FS-N10 Series User's Manual -2-1Installing Sensor AmplifiersMounting on a DIN rail1Align th

Strona 26 - Switching Output

2-1 Installing Sensor Amplifiers2Installation and Connection2-3- Digital Fiber Sensor FS-N10 Series User's Manual - • Contact your nearest KEYEN

Strona 27 - Adjusting Sensitivity

2-1 Installing Sensor Amplifiers2Installation and Connection2-4- Digital Fiber Sensor FS-N10 Series User's Manual - · Be sure to turn off the po

Strona 28 - Disabling the preset function

2-1 Installing Sensor Amplifiers2Installation and Connection2-5- Digital Fiber Sensor FS-N10 Series User's Manual -Wiring Diagrams for M8/e-CON

Strona 29 - Current value is "

IntroductionThis manual describes the basic operations and hardware functions of the FS-N10 Series. Read the manual carefully to ensure safe performa

Strona 30 - Workpiece

2Installation and Connection2-6- Digital Fiber Sensor FS-N10 Series User's Manual -2-2Connecting the Fiber UnitThis section provides procedures f

Strona 31 - Full Auto Preset Function

2-2 Connecting the Fiber Unit2Installation and Connection2-7- Digital Fiber Sensor FS-N10 Series User's Manual -5Insert the fiber unit into the

Strona 32

2-2 Connecting the Fiber Unit2Installation and ConnectionMEMO2-8- Digital Fiber Sensor FS-N10 Series User's Manual -

Strona 33

33-1- Digital Fiber Sensor FS-N10 Series User's Manual -Basic OperationThis chapter explains basic instructions for operating and setting thesens

Strona 34

3Basic Operation3-2- Digital Fiber Sensor FS-N10 Series User's Manual -3-1Quick ReferenceThe main setting operations are explained according to p

Strona 35 - Full Auto Calibration

3-1 Quick Reference3Basic Operation3-3- Digital Fiber Sensor FS-N10 Series User's Manual -* Not available for the FS-N10 Series shipped before M

Strona 36

3Basic Operation3-4- Digital Fiber Sensor FS-N10 Series User's Manual -3-2Switching OutputThis function configures when the output turns ON.1When

Strona 37 - Zero shift calibration

3Basic Operation3-5- Digital Fiber Sensor FS-N10 Series User's Manual -3-3Adjusting SensitivityThis manual refers to the values that select ON/OF

Strona 38 - Current vallue is "

3-3 Adjusting Sensitivity3Basic Operation3-6- Digital Fiber Sensor FS-N10 Series User's Manual -Enabling the preset functionWhen the PST indicat

Strona 39

3-3 Adjusting Sensitivity3Basic Operation3-7- Digital Fiber Sensor FS-N10 Series User's Manual -This function calibrates the current value to &q

Strona 40 - Saturation Canceling function

196141ESafety Precautions •Do not wire the amplifier line along with power lines or high-tension lines, as the sensor may malfunction or be damaged du

Strona 41 - Selecting Recipe

3-3 Adjusting Sensitivity3Basic Operation3-8- Digital Fiber Sensor FS-N10 Series User's Manual -This function calibrates the reference state to

Strona 42

3-3 Adjusting Sensitivity3Basic Operation3-9- Digital Fiber Sensor FS-N10 Series User's Manual -This function automatically judges 2 states (wor

Strona 43 - Initialization

3-3 Adjusting Sensitivity3Basic Operation3-10- Digital Fiber Sensor FS-N10 Series User's Manual -Disabling the full auto preset functionWhen the

Strona 44 - Locking in MEGA Mode

3-3 Adjusting Sensitivity3Basic Operation3-11- Digital Fiber Sensor FS-N10 Series User's Manual -Two-point calibration is the most basic method

Strona 45 - Disabling the Key Operation

3-3 Adjusting Sensitivity3Basic Operation3-12- Digital Fiber Sensor FS-N10 Series User's Manual -This sensitivity setting method is useful if th

Strona 46 - Key Lock with PIN Number

3-3 Adjusting Sensitivity3Basic Operation3-13- Digital Fiber Sensor FS-N10 Series User's Manual -This method automatically sets sensitivity usin

Strona 47

3-3 Adjusting Sensitivity3Basic Operation3-14- Digital Fiber Sensor FS-N10 Series User's Manual -This method is used when you want to position a

Strona 48 - List of Settings

3-3 Adjusting Sensitivity3Basic Operation3-15- Digital Fiber Sensor FS-N10 Series User's Manual -Percentage calibrationA setting value is establ

Strona 49

3Basic Operation3-16- Digital Fiber Sensor FS-N10 Series User's Manual -3-4Setting the Current Received Light Intensity to 0 (Zero Shift)This fun

Strona 50 - Basic Settings

3-4 Setting the Current Received Light Intensity to 0 (Zero Shift)3Basic Operation3-17- Digital Fiber Sensor FS-N10 Series User's Manual -The ze

Strona 51

Safety PrecautionsMEMO- Digital Fiber Sensor FS-N10 Series User's Manual -2

Strona 52 - Setting example

3Basic Operation3-18- Digital Fiber Sensor FS-N10 Series User's Manual -3-5Light emission/Received light intensity adjustment (Saturation Canceli

Strona 53 - Detection Settings (Func)

3Basic Operation3-19- Digital Fiber Sensor FS-N10 Series User's Manual -3-6Loading the Recommended Settings (Recipe Function)The FS-N10 Series ha

Strona 54 - Detection Mode

3-6 Loading the Recommended Settings (Recipe Function)3Basic Operation3-20- Digital Fiber Sensor FS-N10 Series User's Manual -* Not available fo

Strona 55 - 100.0"

3Basic Operation3-21- Digital Fiber Sensor FS-N10 Series User's Manual -3-7InitializationThe sensor amplifier can be reset to the factory default

Strona 56

3Basic Operation3-22- Digital Fiber Sensor FS-N10 Series User's Manual -3-8Locking in MEGA ModeThis function is available for the 1-output type m

Strona 57 - .0"

3Basic Operation3-23- Digital Fiber Sensor FS-N10 Series User's Manual -3-9Disabling the Key OperationThe key lock function disables all key oper

Strona 58

3-9 Disabling the Key Operation3Basic Operation3-24- Digital Fiber Sensor FS-N10 Series User's Manual -A PIN number can be set when activating k

Strona 59 - Display example

44-1- Digital Fiber Sensor FS-N10 Series User's Manual -Settings for Advanced FunctionsThis chapter describes settings for advanced functions of

Strona 60 - Area detection mode

4Settings for Advanced Functions4-2- Digital Fiber Sensor FS-N10 Series User's Manual -4-1List of SettingsBasic Settings…(page 4-4)Detection

Strona 61

4-1 List of Settings4Settings for Advanced Functions4-3- Digital Fiber Sensor FS-N10 Series User's Manual -2-output Settings ( )*12…(page 4-35

Strona 62 - Edge detection mode

12345- Digital Fiber Sensor FS-N10 Series User's Manual -36Manual OrganizationOutlines the package contents and identifies part names and functio

Strona 63 - External Input

4Settings for Advanced Functions4-4- Digital Fiber Sensor FS-N10 Series User's Manual -4-2Basic SettingsThe detection stability will increase whe

Strona 64 - Thrubeam model

4-2 Basic Settings4Settings for Advanced Functions4-5- Digital Fiber Sensor FS-N10 Series User's Manual -Percentage calibrationSetup value can b

Strona 65 - Sleep function

4-2 Basic Settings4Settings for Advanced Functions4-6- Digital Fiber Sensor FS-N10 Series User's Manual -Zero shift calibrationThis sensitivity

Strona 66

4Settings for Advanced Functions4-7- Digital Fiber Sensor FS-N10 Series User's Manual -4-3Detection Settings (Func)There are 3 types of timers av

Strona 67

4-3 Detection Settings (Func)4Settings for Advanced Functions4-8- Digital Fiber Sensor FS-N10 Series User's Manual -The table below lists the de

Strona 68

4-3 Detection Settings (Func)4Settings for Advanced Functions4-9- Digital Fiber Sensor FS-N10 Series User's Manual -DATUM1 modeIn DATUM1 mode, t

Strona 69 - Inverted display

4-3 Detection Settings (Func)4Settings for Advanced Functions4-10- Digital Fiber Sensor FS-N10 Series User's Manual - • When the received light

Strona 70 - Sub-display

4-3 Detection Settings (Func)4Settings for Advanced Functions4-11- Digital Fiber Sensor FS-N10 Series User's Manual -DATUM2 modeIn DATUM2 mode,

Strona 71 - Light intensity hold display

4-3 Detection Settings (Func)4Settings for Advanced Functions4-12- Digital Fiber Sensor FS-N10 Series User's Manual - • When the received light

Strona 72 - Peak value

4-3 Detection Settings (Func)4Settings for Advanced Functions4-13- Digital Fiber Sensor FS-N10 Series User's Manual -Changing the warning outp

Strona 73 - L-on / D-on display

4- Digital Fiber Sensor FS-N10 Series User's Manual -Table of ContentsSafety Precautions...

Strona 74 - Preset Saturation Function

4-3 Detection Settings (Func)4Settings for Advanced Functions4-14- Digital Fiber Sensor FS-N10 Series User's Manual -Area detection modeIn this

Strona 75

4-3 Detection Settings (Func)4Settings for Advanced Functions4-15- Digital Fiber Sensor FS-N10 Series User's Manual -Methods for setting upper

Strona 76 - System Settings (SYS)

4-3 Detection Settings (Func)4Settings for Advanced Functions4-16- Digital Fiber Sensor FS-N10 Series User's Manual -Edge detection modeIn the e

Strona 77 - Power Save

4-3 Detection Settings (Func)4Settings for Advanced Functions4-17- Digital Fiber Sensor FS-N10 Series User's Manual -On sensor amplifiers with a

Strona 78 - Display Gain

4-3 Detection Settings (Func)4Settings for Advanced Functions4-18- Digital Fiber Sensor FS-N10 Series User's Manual -Pause functionDuring signal

Strona 79 - Interference Prevention

4-3 Detection Settings (Func)4Settings for Advanced Functions4-19- Digital Fiber Sensor FS-N10 Series User's Manual -Sleep functionThis function

Strona 80

4-3 Detection Settings (Func)4Settings for Advanced Functions4-20- Digital Fiber Sensor FS-N10 Series User's Manual -When a fiber unit having st

Strona 81 - 2-output Settings ( )

4-3 Detection Settings (Func)4Settings for Advanced Functions4-21- Digital Fiber Sensor FS-N10 Series User's Manual -The FS-N11MN is equipped wi

Strona 82 - Limit setting output mode

4-3 Detection Settings (Func)4Settings for Advanced Functions4-22- Digital Fiber Sensor FS-N10 Series User's Manual -The analog output can be au

Strona 83 - Warning output mode

4Settings for Advanced Functions4-23- Digital Fiber Sensor FS-N10 Series User's Manual -4-4Display Settings (diSP)The current value and setting v

Strona 84 - Output Timer for Output2

Table of Contents5- Digital Fiber Sensor FS-N10 Series User's Manual -3-5Light emission/Received light intensity adjustment (Saturation Canceling

Strona 85 - Settings Save/Recall

4-4 Display Settings (diSP)4Settings for Advanced Functions4-24- Digital Fiber Sensor FS-N10 Series User's Manual -Displaying a sub displayAft

Strona 86 - User Reset (Settings Recall)

4-4 Display Settings (diSP)4Settings for Advanced Functions4-25- Digital Fiber Sensor FS-N10 Series User's Manual -Excess gain (%) displayReceiv

Strona 87 - Specifications

4-4 Display Settings (diSP)4Settings for Advanced Functions4-26- Digital Fiber Sensor FS-N10 Series User's Manual -Timing chart for standard s

Strona 88

4-4 Display Settings (diSP)4Settings for Advanced Functions4-27- Digital Fiber Sensor FS-N10 Series User's Manual -Excess gain hold (%) displayT

Strona 89 - 2-Output Type

4-4 Display Settings (diSP)4Settings for Advanced Functions4-28- Digital Fiber Sensor FS-N10 Series User's Manual -The saturation level can be s

Strona 90 - Monitor Output Type

4-4 Display Settings (diSP)4Settings for Advanced Functions4-29- Digital Fiber Sensor FS-N10 Series User's Manual -Operating principles of the p

Strona 91 - Zero Line Type

4Settings for Advanced Functions4-30- Digital Fiber Sensor FS-N10 Series User's Manual -4-5System Settings (SYS)The APC (Auto Power Control) func

Strona 92 - Input/Output Circuit Diagram

4-5 System Settings (SYS)4Settings for Advanced Functions4-31- Digital Fiber Sensor FS-N10 Series User's Manual -Power consumption can be reduce

Strona 93 - Monitor output type

4-5 System Settings (SYS)4Settings for Advanced Functions4-32- Digital Fiber Sensor FS-N10 Series User's Manual -Received light intensity can be

Strona 94 - Dimensions

4-5 System Settings (SYS)4Settings for Advanced Functions4-33- Digital Fiber Sensor FS-N10 Series User's Manual -Malfunction may result from &qu

Strona 95 - /N13CP/N14CP

Table of Contents6- Digital Fiber Sensor FS-N10 Series User's Manual -5-1 Specifications...

Strona 96 - FS-N11EN/12EN

4-5 System Settings (SYS)4Settings for Advanced Functions4-34- Digital Fiber Sensor FS-N10 Series User's Manual -Some operations on the main uni

Strona 97 - When mounted on DIN rail

4Settings for Advanced Functions4-35- Digital Fiber Sensor FS-N10 Series User's Manual -4-62-output Settings ( )*This function is only available

Strona 98 - 5-3 Dimensions

4-6 2-output Settings ( )4Settings for Advanced Functions4-36- Digital Fiber Sensor FS-N10 Series User's Manual -Limit setting output modeSettin

Strona 99

4-6 2-output Settings ( )4Settings for Advanced Functions4-37- Digital Fiber Sensor FS-N10 Series User's Manual -Warning output modeIf output 2

Strona 100 - Troubleshooting

4-6 2-output Settings ( )4Settings for Advanced Functions4-38- Digital Fiber Sensor FS-N10 Series User's Manual -There are 3 types of timers ava

Strona 101 - Appendix

4Settings for Advanced Functions4-39- Digital Fiber Sensor FS-N10 Series User's Manual -4-7Settings Save/RecallThe current setting value and adva

Strona 102

4-7 Settings Save/Recall4Settings for Advanced Functions4-40- Digital Fiber Sensor FS-N10 Series User's Manual -The settings saved with the cust

Strona 103

55-1- Digital Fiber Sensor FS-N10 Series User's Manual -SpecificationsThis chapter provides the specifications, circuit diagrams anddimensions of

Strona 104 - L_d selected) 50 4-16

5Specifications5-2- Digital Fiber Sensor FS-N10 Series User's Manual -5-1Specifications*1 For M8 and e-CON connector types, cable length must be

Strona 105 - Reference

5-1 Specifications5Specifications5-3- Digital Fiber Sensor FS-N10 Series User's Manual -*1 For M8 connector type, cable length must be 30 m or l

Strona 106

11-1- Digital Fiber Sensor FS-N10 Series User's Manual -Before UsingThis chapter outlines the package contents and identifies part names and func

Strona 107

5-1 Specifications 5Specifications5-4- Digital Fiber Sensor FS-N10 Series User's Manual -*1 SUPER: 1.2ms, ULTRA:1.8ms, MEGA: 4.2ms 63% response*

Strona 108

5-1 Specifications5Specifications5-5- Digital Fiber Sensor FS-N10 Series User's Manual -*1 Counted as 1-output unit. when connected to the commu

Strona 109 - 6-5 Index

5Specifications5-6- Digital Fiber Sensor FS-N10 Series User's Manual -5-2Input/Output Circuit Diagram1-Output TypeFS-N11N / N12N FS-N11P / N12PFS

Strona 110 - Quick Reference

5-2 Input/Output Circuit Diagram5Specifications5-7- Digital Fiber Sensor FS-N10 Series User's Manual -FS-N13CP/N14CP0 V12 to 24 VDC* FS-N13CP on

Strona 111

5Specifications5-8- Digital Fiber Sensor FS-N10 Series User's Manual -5-3DimensionsFS-N11□/N12□/N13□/N14□/N11MN/N10* 1 FS-N11N(P)/N13N(P)/N11MN i

Strona 112 - List of settings

5-3 Dimensions5Specifications5-9- Digital Fiber Sensor FS-N10 Series User's Manual -FS-N11C□/N12C□/N13CP/N14CP* 1 FS-N11CN(P)/N13CP/ is not prov

Strona 113

5-3 Dimensions 5Specifications5-10- Digital Fiber Sensor FS-N10 Series User's Manual -FS-N11EN/12EN* 1 FS-N11EN is not provided with an expansio

Strona 114

5-3 Dimensions5Specifications5-11- Digital Fiber Sensor FS-N10 Series User's Manual -End unit (OP-26751)53.835.4620.8(22.6)9.2When mounted on DI

Strona 115 - WARRANTIES AND DISCLAIMERS

5-3 Dimensions 5Specifications5-12- Digital Fiber Sensor FS-N10 Series User's Manual -MEMO

Strona 116

66-1- Digital Fiber Sensor FS-N10 Series User's Manual -AppendixThis chapter provides troubleshooting instructions and initial settings(default v

Komentarze do niniejszej Instrukcji