2
Installation and Connection
2-6
- Digital Fiber Sensor FS-N10 Series User's Manual -
2-2
Connecting the Fiber Unit
This section provides procedures for connecting the fiber unit and operating
precautions.
1
Install the fiber unit.
After the installation, check that the transmitter and receiver of the sensor are
spaced properly. Also check that the optical axis is aligned.
2
If the fiber unit is a free cut type, cut any excess length of the fiber.
(1) Insert the fiber into the hole in the cutter.
(2) Bring down the blade in a single, swift motion to cut the fiber.
Failure to observe the cautions below may result in an improperly
cut surface, which may reduce the detection distance.
· When cutting the fiber unit, be sure to use a gray fiber cutter
(OP-87098)
· Cut the fiber unit in a single motion without stopping the blade
halfway through.
· Do not use the same hole twice.
3
Open the dust cover in the
direction of arrow (1).
4
Move the fiber lock lever down in
the direction of arrow (2).
Fiber
(2)
(1)
Always insert fiber from the side with writing
.
Fiber cutter
(OP-87098)
Point
(1)
(2)
(3)