
3
Basic Operation
3-18
- Digital Fiber Sensor FS-N10 Series User's Manual -
3-5
Light emission/Received light intensity adjustment (Saturation Canceling)
When a fiber unit having strong power (longer detection range) is used at a close
range, the received light intensity may remain unchanged from the maximum value in
the display-enabled range (saturated) regardless of whether a workpiece is present or
not. (Example: Numerical value does not change from 9999)
In such a case, the light emission and the received light intensity can be automatically
corrected to optimal state by using the saturation Canceling function.
■ Enabling the saturation Canceling function
1
Press the [SET] button while holding down the [MODE] button.
The received light intensity corresponding to the power mode is set within the
range as shown in the following table.
■ Disabling the saturation Canceling function
1
Press the [SET] button while holding down the [MODE] button.
Saturation Canceling function
Power mode
Setting range of
received light intensity
HSP、FINE、TURBO
2047±350
SUPER 4095±500
ULTRA、MEGA
5000±600
Komentarze do niniejszej Instrukcji