2-2 Connecting and Mounting the Sensor Head
2-10
2
Installation and Connection
IB-E
2
Attach the lock cover to the connector to secure the cable.
3
Attach the transmitter’s sensor head connection cable to the amplifier’s
[T] connector.
The connection procedures are the same as the receiver side.
Point
When removing the sensor head connection cable, push
the lock lever and pull it out.
DIN rail mount type
(IB-1000/IB-1050)
Panel mount type
(IB-1500/IB-1550)
Locked
Lock cover
Lock lever
Top is [T] side