2-2 Connecting and Mounting the Sensor Head
2-11
IB-E
2
Installation and Connection
Attaching the sensor head cable connector (OP-87060)
Cut the sensor head cable to the required length and attach the new connector to use the
sensor. The connection method is the same for the transmitter and receiver.
1
Cut the cable to the required length and strip approx. 15 mm of insulation
from the end.
2
Insert each color coded cable into the same colored marked points on the
connector.
Each cable is secured temporarily when it is inserted completely.
3
Confirm that all the cables are inserted properly into the connector and
crimp them using pliers or a similar tool.
Do not strip the core wire insulation.
Once the connector has been installed, make sure to connect
it to the amplifier and confirm that the sensor operates
normally.
If the sensor head does not function properly, crimp the
connector again using pliers or a similar tool.
Once the connector is crimped, it cannot be reused.
Insert further
than here.